Application Scenarios
A rotary indexing machine needed to activate a clamp, start a fill operation, and release a discharge gate at different angles during each revolution. Mechanical limit switches had previously been adjusted by hand, creating setup variations and additional panel wiring. The maintenance team installed a resolver and configured the 1756-PLS to control the operations through programmable position windows.
Instead of adding more physical switches, the application used low-limit and high-limit setpoints to define when each output should turn on and off. The machine could then be reconfigured by changing setpoint values rather than moving hardware switches. This reduced mechanical adjustment time and made product-change records easier to manage.
The value of the 1756-PLS in this application was not simply the number of inputs and outputs. Its main advantage was the ability to convert a resolver position into multiple, repeatable limit-switch events inside one ControlLogix module.
Parameter
| Main Parameters | Value/Description |
|---|---|
| Product Model | 1756-PLS |
| Manufacturer | Rockwell Automation |
| Brand | Allen-Bradley |
| Product Category | Programmable limit switch module |
| Compatible Platform | ControlLogix 1756 |
| Intended Controller | Logix5550 controller |
| Inputs | 16 single-ended inputs, 10–31.2V DC |
| Outputs | 16 current-sourcing outputs, 10–31.2V DC |
| Output Current | 1 A maximum per output |
| Output Configuration | 4 groups of 4 outputs with separate power and common |
| Input Configuration | 4 groups of 4 inputs with separate common |
| Position Feedback | Compatible Allen-Bradley resolver |
| Resolver Excitation | 2V rms ±20% at 5 kHz ±20% |
| Angular Resolution | 0.088° per bit |
| Accuracy | ±0.0976% of full scale |
| Repeatability | ±0.0488% of full scale |
| Maximum Tracking Rate | ±1800 RPM |
| Backplane Current | 1 A at 5.1V DC; 125 mA at 24V DC |
| Power Dissipation | 25.7 W at 30 °C; 21.3 W at 60 °C |
| Isolation | 250V continuous between I/O groups and between the resolver and backplane |
| Chassis Requirement | Three contiguous slots |
| Terminal Blocks | Three removable terminal blocks; 1756-TBSH or 1756-TBNH |
| Operating Temperature | 0…60 °C (32…140 °F) |
| Humidity | 5…95% noncondensing |
| Agency Ratings | UL, CSA, CE, and Class I Division 2 |
| Lifecycle Status | Discontinued; no planned Rockwell Automation replacement |
Technical Principles and Innovative Values
- Innovation Point 1: Position-based limit switching without additional mechanical switches. The 1756-PLS monitors resolver position and controls outputs according to configured limits. A single module can replace several mechanical limit switches in suitable rotary and indexing applications.
- Innovation Point 2: Flexible on/off position windows. Each limit-switch function can be configured with low-limit and high-limit setpoints. The output turns on when the axis reaches the low-limit position and turns off at the high-limit position. Multiple position windows can also be configured for one output during a single resolver rotation.
- Innovation Point 3: Programmable setpoint adjustment. Setpoints are configured through compatible Rockwell Automation control software rather than adjusted by physically moving switches. This makes product changes, rotary-table stations, and packaging-machine formats easier to modify while preserving a centralized configuration record.
- Innovation Point 4: Separate input and output groups. The 16 inputs and 16 outputs are arranged in four groups of four, each with its own common or power/common arrangement. This grouping provides useful electrical separation for different field devices and wiring circuits.
- Innovation Point 5: Integrated resolver interface and I/O in one three-slot module. The 1756-PLS combines resolver signal processing with digital inputs and current-sourcing outputs. The central section handles the resolver interface and I/O control, while the left and right sections provide the field I/O connections.