ABB 1SAR330020R0000 CT-MFD Electronic Time Relay – 24–240V AC/DC Multifunction Timer, 0.1 s–100 h, 16 A SPDT

ABB 1SAR330020R0000 CT-MFD Electronic Time Relay – 24–240V AC/DC Multifunction Timer, 0.1 s–100 h, 16 A SPDT

Product Overview

The ABB 1SAR330020R0000​ is ABB’s C565 / CT-MFD-series multifunction electronic time relay, positioned in ABB’s low-voltage control products portfolio as the direct electronic replacement for legacy pneumatic (air-damp) and electromechanical cam timers in industrial control cabinets, MCC lineups, and DCS/PLC I/O front-end panels. The “1SAR” material number places it in ABB’s modular DIN-rail control component family, and ABB 1SAR330020R0000​ specifically denotes the wide-range 24–240 V AC/DC universal-supply version of the CT-MFD multifunction timer—meaning one SKU covers everything from 24 V DC panel-bus logic systems to 230 V AC mains-fed starter panels without jumper or hardware change.
At the functional level, ABB 1SAR330020R0000​ integrates eight commonly used timing modes—ON-delay, OFF-delay, interval (single-shot), repeat cycle (pulse/pause), star-delta changeover, cumulative pulse, and several derivative variants—selectable via a front rotary DIP + potentiometer arrangement on the 22.5 mm wide fascia. Time setting spans 0.1 s to 100 h across multiple decade ranges, with quartz-derived timebase holding ±1 % accuracy and ±20 ms repeatability, a full order of magnitude tighter than the ±10 % to ±20 % typical of pneumatic dampers that drift with humidity and temperature. The output stage is a single C/O (SPDT, 1 NO + 1 NC) silver-alloy contact rated 16 A @ 250 V AC resistive, giving the relay enough muscle to directly switch ABB A16 / A26-size contactor coils in motor starters without an intervening interposing relay—a detail that matters in compact MCC buckets where DIN rail real estate is scarce.
In automation-system terms, ABB 1SAR330020R0000​ sits in the “hard-wired logic” layer that still surrounds every DCS and PLC: pump lead-lag sequencing, star-delta motor starters, anti-condensation heater timers, HVAC damper delays, conveyor interlock blanking, and—increasingly—as an EMI-hardened delay filter on PLC digital inputs that need debounce outside the scan. Where a Siemens S7-1200/1500 or Rockwell CompactLogix rack handles the supervisory logic, the ABB 1SAR330020R0000​ handles the “must-work-even-if-the-processor-is-in-program” local timing—MCC-door pushbutton sequences, starter-cell anti-nuisance-delay, or guaranteed-fallback pump autostart on communication loss. Passed through IEC 61000-4 EMC testing and carrying CE / UL / cUL / CCC / IEC 61812-1, the module is globally deployable from European 230 V panels to North American 120 V control circuits and Asian 24 V DC skid builds. For maintenance buyers, the universal-voltage trick means one spare covers AC and DC fleets alike—a storeroom simplification that explains why ABB 1SAR330020R0000​ is a top-moving SKU in ABB timer spares.

ABB 1SAR330020R0000 CT-MFD Electronic Time Relay – 24–240V AC/DC Multifunction Timer, 0.1 s–100 h, 16 A SPDT

Technical Specifications

Parameter Name Parameter Value
Product Model 1SAR330020R0000
Manufacturer ABB (Low Voltage Products – Control Components)
Product Type Multifunction Electronic Time Relay (CT-MFD / C565 series)
Supply Voltage 24–240 V AC / DC, 50/60 Hz (auto-sensing, no jumper)
Power Consumption ≤ 2.5 W
Time Range 0.1 s – 100 h (multi-range selector)
Timing Modes 8 functions: ON-delay, OFF-delay, interval, repeat cycle, star-delta, pulse, cumulative, etc.
Timebase Accuracy ±1 % of setting ±20 ms (quartz oscillator)
Output Contact 1 C/O (SPDT: 1 NO + 1 NC)
Contact Rating 16 A @ 250 V AC (resistive); 30 V DC rating per IEC
Electrical Life ≥ 100.000 operations @ 16 A, 250 V AC
Mechanical Life ≥ 10.000.000 operations
Indication Bi-color LED (green = supply, red = output energized)
Mounting TH35 DIN rail (IEC 60715), 22.5 mm width
Operating Temp. -25 °C to +55 °C
Protection IP20 (housing) / IP40 (terminals)
Agency Approvals CE, UL, cUL, CCC, IEC 61812-1. IEC 61000-4 EMC

Main Features and Advantages

Universal 24–240 V AC/DC supply eliminates SKU sprawl.​ The headline advantage of ABB 1SAR330020R0000​ is its auto-sensing wide-range front end: 24 V DC panel bus, 48 V DC telecom-derived control, 120 V AC North-American MCC, 230 V AC European starter—same relay, no jumpers, no dip-switch voltage select. For EPC firms and system integrators running multi-region projects (e.g., a German OEM skid shipping to a US plant with 120 V control and a Middle-East site with 230 V), one ABB 1SAR330020R0000​ spare covers all three. Storeroom managers particularly value this—ABB’s older CT-A (ON-delay only, single-voltage) and CT-E (OFF-delay only) families spawned AC/DC-split SKUs that doubled inventory; the CT-MFD in ABB 1SAR330020R0000​ collapses that matrix.

Eight timing modes in a 22.5 mm shell.​ Where a single-function timer forces you to pick “ON-delay or OFF-delay” at procurement time, ABB 1SAR330020R0000​ carries all eight on the front rotary switch. Star-delta motor starting is the classic case: traditional schemes need two timers (main ON-delay for delta-switch, plus a second for star-contactor overlap), whereas ABB 1SAR330020R0000​ handles the whole sequence—main contactor close → delay → open star, close delta—on one 22.5 mm slice. In pump lead-lag panels, the same relay toggles between interval (fixed run-time) and repeat-cycle (duty/rest) by rotating the knob, no rewiring. Commissioning engineers working across varied panels appreciate that ABB 1SAR330020R0000​ adapts to the drawing rather than the other way around.

16 A SPDT contact kills the interposing relay.​ Most electronic timers cap at 5–8 A, forcing an interposing relay (e.g., ABB CR-M / Finder 60 series) between timer and contactor coil—extra DIN slice, extra failure point, extra wiring. ABB 1SAR330020R0000​ rates 16 A @ 250 V AC on the C/O directly, which covers the coil inrush of ABB A16 (up to 7.5–11 kW motor starters) and many A26 applications without help. Silver-alloy contact material plus ABB’s arc-quench geometry keeps the contact from welding during repetitive starter cycling. That said, best practice still dictates contactor-coil interposition for >16 A contactors or highly inductive DC coils—ABB 1SAR330020R0000​ is honest about its 30 V DC rating ceiling.

Quartz timebase and EMC hardening for VFD-rich panels.​ Cheap timers drift when a 75 kW drive kicks in next door; ABB 1SAR330020R0000​ uses a quartz crystal derived timebase (±1 % ±20 ms) that holds through temperature swing and supply ripple, and the PCB layout + screened enclosure pass IEC 61000-4 surge/ESD/EFT, so the relay sits calmly in a full VFD MCC where three ABB ACS880 drives are switching 415 V on the same bus. The bi-color LED is a small but valued field touch—green for “supply alive,” red for “output timed in”—letting a maintenance tech diagnose “timer didn’t pick up” vs “timer picked but load didn’t” without a meter.

Drop-in for legacy pneumatics and competitor timers.​ Plants retiring old ABB EMR / pneumatic dampers (the ones with the little adjustment wheel that sticks in humid summers) find ABB 1SAR330020R0000​ pins out identically on 22.5 mm DIN with screw terminals, and the 8-mode set covers every pneumatic function plus extras. Cross-migration from Crouzet 888 / Finder 80 series / Schneider RE17 is straightforward on terminal layout; the universal voltage means the swap rarely needs a PSU change. For MRO buyers standardizing a site’s timer SKU list, ABB 1SAR330020R0000​ displaces 3–4 legacy singles into one multisource part.

Application Field

The ABB 1SAR330020R0000​ lands wherever a DCS/PLC needs a local, hard-wired timing element that survives processor mode, comms loss, or scan-cycle limitations—and wherever motor/pump/valve sequencing still runs on conventional contactor logic alongside the digital layer. The densest deployment is motor control centers (MCCs): star-delta starters for pumps, fans, and compressors in water treatment, HVAC plant rooms, and process skids routinely use ABB 1SAR330020R0000​ for the delta-transition timer, with the 16 A contact driving the delta contactor directly. In combined-cycle and biomass plants where ABB Ovation or Siemens T3000 supervise the BOP, local MCC buckets for CW pumps, BFPT lube-oil skids, and ash-handling conveyors still carry hard-wired starter sequences—ABB 1SAR330020R0000​ is the timer of choice because its -25 °C cold-start and 55 °C sustained rating suit both indoor MCC and semi-exposed pump-house panels.

Pump lead-lag and duty-standby sequencing​ is a second major lane. In municipal water lift stations and industrial cooling-water loops, ABB 1SAR330020R0000​ in repeat-cycle or interval mode enforces minimum run-time on the lead pump before allowing hand-off-auto transfer, and provides a “cool-down” pause before the standby restarts—logic that is often kept hard-wired so the PLC’s downtime (e.g., during a TIA Portal download) doesn’t stall the pumps. The relay’s 0.1 s lower bound also lets it serve as a debounce / nuisance-trip blanking element on PLC DI points that see contactor bounce or float-switch chatter.

HVAC and building-services panels​ consume the relay heavily in AHU/fan-coil sequences: damper-motor pre-purge delay before fan start, frost-stat override timing, heating-element staging via contactor, and night-setback lighting relays in plant corridors. Here the ABB 1SAR330020R0000​ 230 V AC native supply is the win—no separate 24 V DC PSU needed in a small AHU panel that otherwise runs on 230 V control.

Conveyor and packaging machinery​ represent the OEM skid market: infeed delay, accumulation zone dwell, star-wheel index timing, and safety-gate re-arm delays all land on ABB 1SAR330020R0000​ because the 100 h upper range covers long dwell/soak cycles (e.g., adhesive cure timers on a labeling head) while the 0.1 s floor catches high-speed indexing. Machine-builders shipping CE-marked panels to both EU and NA markets lean on the universal-voltage ABB 1SAR330020R0000​ to keep one BOM across destinations.

Retrofit context closes the loop: plants running 15–20 year old pneumatic ABB / Crouzet / P&B timers face drift complaints and spare obsolescence. Swapping to ABB 1SAR330020R0000​ recovers ±1 % accuracy, eliminates seasonal drift, and collapses the spare SKU count. For maintenance managers, keeping 3–5 cold-spare ABB 1SAR330020R0000​ on the storeroom rack covers star-delta starters, pump timers, HVAC dams, and conveyor delays across the whole site—a rare “one-SKU-covers-most” win in industrial MRO.