TRICONEX 3008

TRICONEX 3008

Key Parameters & Specifications (Consolidated)

Category Specification Notes (Critical Distinctions)
Manufacturer TRICONEX (Schneider Electric Process Safety) Safety-focused TMR system specialist
Product Type 4-channel analog output module (4–20 mA DC) TMR-compatible; for safety-critical actuator control
Primary Function Generation of 4–20 mA DC control signals; channel isolation; TMR majority voting; fault diagnostics Drives field actuators in safety instrumented loops
Output Channels 4 independent, galvanically isolated channels Each channel is isolated from others and backplane to avoid interference
Output Signal Type 4–20 mA DC current loop Configurable scaling via TriStation software (e.g., 4 mA = 0% setpoint, 20 mA = 100% setpoint)
Output Accuracy ±0.1% of full scale (4–20 mA) High precision for closed-loop control applications
Output Load Capacity Up to 750 Ω (at 24 V DC supply) Compatible with most industrial actuators and signal conditioners
Output Isolation Channel-to-channel: 500 V DC; Channel-to-backplane: 1500 V DC Prevents ground loops and protects the module from field-side transients
Protection Features Built-in short-circuit protection; over-current detection; signal drift monitoring Faults are reported to the TMR controller for operator notification
Power Supply Powered by TRICONEX controller backplane No external power required; draws power from the TMR chassis
Compatibility TRICONEX 3000, 4000, 5000 series TMR safety controllers Verify controller firmware version for full compatibility
Environmental Ratings – Operating Temperature: 0 °C to +60 °C

– Storage Temperature: -40 °C to +85 °C

– Humidity: 5–95% RH (non-condensing)

– Vibration: 5 g RMS (5–500 Hz, per IEC 60068-2-6)

Suitable for harsh industrial environments; install in a climate-controlled cabinet
Mechanical Specifications – Form Factor: TRICONEX standard chassis module

– Mounting: TRICONEX TMR controller chassis slot

– Protection Rating: IP20 (cabinet-mounted only)

– Weight: ~0.7 kg (typical)

Hot-swappable; supports online maintenance without SIS downtime
Safety Certifications IEC 61508 SIL 3; TÜV Rheinland certified; FM Approved; CSA Certified Compliant with global safety standards for SIS applications
Diagnostic Features Open-circuit detection; over-current alarms; signal drift alerts; self-diagnostics Enables predictive maintenance and rapid fault troubleshooting

Critical Notes (Avoid Common Mistakes)

TRICONEX 3008

  1. Safety System Exclusivity: The TRICONEX 3604E is designed exclusively for TRICONEX TMR safety controllers. Do not use it with non-TRICONEX PLC/DCS systems.
  2. Load Resistance Limits: Do not exceed the 750 Ω maximum load resistance; under-loaded or over-loaded circuits may cause signal distortion or module damage.
  3. Hot-Swap Operation: Follow TRICONEX safety procedures for hot-swapping—ensure the module is properly aligned with the chassis slot to avoid damaging backplane pins or disrupting the SIS.
  4. Isolation Requirements: Do not bypass channel isolation; improper wiring may lead to ground loops, signal interference, or catastrophic module failure.