TRICONEX 2700

TRICONEX 2700

Product Name

TRICONEX 2700 Main Processor Module; TMR Safety System Core Computing Unit for Triple Modular Redundancy Control (TRICONEX by Schneider Electric Process Safety).

Product Description

The TRICONEX 2700 is a high-reliability main processor module that serves as the central computing core of TRICONEX TMR safety controllers, targeted at high-risk industrial applications such as oil & gas refining, chemical processing, power generation, and petrochemical plant operations. It is the key component that enables the TMR architecture’s core function: triple modular redundancy with majority voting logic to eliminate single points of failure.
Each TRICONEX TMR system requires three redundant 2700 processor modules to operate—all three modules execute the same safety application program simultaneously, cross-validate data in real time, and use majority voting to determine the correct output. If one module malfunctions, the remaining two healthy modules maintain system operation without interruption, ensuring compliance with IEC 61508 SIL 3 safety standards.
Key features include high-speed program execution, support for TRICONEX TriStation software for configuration and programming, built-in self-diagnostics for proactive fault detection, and compatibility with all TRICONEX I/O modules and communication interfaces. The module is hot-swappable, allowing online replacement without shutting down the safety instrumented system, which minimizes process downtime during maintenance. It is ideal for applications where uninterrupted control and personnel/equipment safety are non-negotiable.TRICONEX 2700

Key Parameters & Specifications (Consolidated)

Category Specification Notes (Critical Distinctions)
Manufacturer TRICONEX (Schneider Electric Process Safety) Safety-focused TMR system specialist
Product Type Main Processor Module (TMR Core Computing Unit) Not a general-purpose PLC CPU; exclusive to TRICONEX TMR SIS
Primary Function TMR program execution; real-time data cross-validation; majority voting logic; system diagnostics; I/O and communication module management Core component for fault-tolerant safety control
Processing Performance Instruction execution time: ≤ 1 μs per boolean instruction; supports up to 10,000 I/O points (system-dependent) Ensures deterministic control for dynamic safety loops
Memory Capacity Program memory: 2 MB; Data memory: 1 MB; Configurable for application expansion Supports complex safety logic and process variable storage
Programming Software TRICONEX TriStation 1131 Compliant with IEC 61131-3 standard
Scroll to Top