DELOMATIC-3 DGU2

DELOMATIC-3 DGU2

DELOMATIC-3 DGU2

We operate ABB and GE aereration, A-B, Honeywell, KUKA, SCHNEIDER, Bentley, TRICONEX, WOODWARD, FOXBORO, WESTINGHOUSE, MOTOROLA, KEBA, kolmorgen, EMERSO N, HIMA Black Horse, industrial and commercial energy storage, container energy storage, household photovoltaic energy storage (peak shaving, valley filling, backup power supply) If needed, please contact us.

 

Origin: The United States

Minimum order quantity :1 piece

Packaging: New raw materials and personalized packaging

Delivery time :2-3 working days

Payment methods: Bank transfer, Western Union

DELOMATIC-3 DGU2

DEIF DELOMATIC-3 DGU2 Integrated Generator Control Unit (GCU) for Marine & Land-Based Power Systems(The naming follows DEIF’s Delomatic-3 series conventions:
  • “DELOMATIC-3”: Identifies DEIF’s flagship generator control system family, optimized for industrial and marine power management.
  • “DGU2”: Stands for “Generator Control Unit (G CU) 2nd-generation,” distinguishing it from legacy DGU1 variants with enhanced processing and connectivity.
  • “Integrated Generator Control Unit”: Highlights its all-in-one functionality—combining control, synchronization, protection, and monitoring to eliminate the need for discrete components.
  • DELOMATIC-3 DGU2

    This module acts as a “generator brain,” orchestrating startup, 并网 (grid connection), and shutdown while safeguarding equipment from electrical faults and ensuring power quality.)

2. Product Description

The DELOMATIC-3 DGU2 is an industrial-grade generator control unit engineered by DEIF to address core challenges in power system management: unstable voltage/frequency regulation, inefficient load distribution, and fragmented system integration. As a flagship model in the Delomatic-3 series, it integrates high-precision PID controlautomatic synchronization, and redundant communication—making it indispensable for:
  • Marine Applications: Controlling main generator sets on commercial ships, oil tankers, and cruise ships, where reliable power ensures navigation system stability and passenger comfort.
  • Land-Based Power Plants: Managing backup power systems for data centers, refineries, and remote industrial sites, supporting black start (grid-independent startup) during outages.
  • Microgrids: Enabling seamless switching between standalone and grid-connected operation, optimizing energy distribution for off-grid communities or industrial parks.
  • Critical Infrastructure: Protecting generator sets in hospitals and emergency facilities, with rapid fault response (<50 ms) to avoid power disruption.

Key Functional Advantages

  1. Tri-Mode Operation & Precise RegulationSupports standalone, grid-connected, and black start modes , adapting to dynamic power demands. Equipped with a built-in PID control module, it delivers voltage regulation accuracy of ±0.5% and frequency stability of ±0.1 Hz—critical for powering sensitive equipment like medical imaging machines or ship navigation systems. The dynamic response time ≤50 ms ensures minimal voltage/frequency deviation during load spikes (e.g., sudden activation of shipboard pumps) 。
  2. Automatic Synchronization & Load DistributionIntegrates a high-precision automatic synchronizer that matches generator voltage, frequency, and phase with the grid or parallel generators before 并网 —preventing electrical transients that could damage alternators. Its intelligent load distribution algorithm evenly allocates power across multiple generator sets, reducing fuel consumption by 8–12% compared to manual operation 。
  3. Comprehensive Protection & Fault DiagnosticsMonitors 10+ electrical parameters (voltage, current, power factor, temperature) and triggers instant protection for overcurrent, overvoltage, undervoltage, overfrequency, underfrequency, and reverse power faults 。 Fault isolation time ≤2 minutes, and the module automatically records event data for post-incident analysis—reducing troubleshooting time by 40%. Dual redundant power inputs with <5 ms switchover ensure uninterrupted operation even if the primary power supply fails 。
  4. Multi-Protocol Connectivity & ScalabilitySupports Modbus RTU and CANopen protocols via 2× RS-485, 1× CAN, and 1× Ethernet interfaces , enabling seamless integration with ship navigation systems, power station SCADA, and DEIF’s own display units (up to 3 DU panels per DGU2). The modular design allows adding I/O expansion modules (DI/DO/AI/AO) without hardware replacement, adapting to generator sets from 500 kW to 2000 kW 。
  5. Rugged Design for Harsh EnvironmentsBuilt with an IP65-rated enclosure and industrial-grade anti-interference circuits , it withstands high temperature (-25°C to +60°C), high humidity (0–95% non-condensing), and dust—ideal for engine rooms, offshore platforms, and desert power sites. The compact 6 TE (30.5 mm width) form factor saves space in densely packed control cabinets 。

3. Product Parameters

3.1 Core Control & Performance Parameters

Parameter Category Technical Specifications
Module Type Integrated Generator Control Unit (GCU)
Supported Operation Modes Standalone, grid-connected, black start
Control Accuracy Voltage: ±0.5% of setpoint; Frequency: ±0.1 Hz
Dynamic Response Time ≤50 ms (voltage/frequency regulation)
Synchronization Function Automatic (voltage, frequency, phase matching)
Load Distribution Intelligent proportional load sharing
Maximum Generator Rating Up to 2000 kW
Data Storage 16 MB (expandable to 32 MB for event logs)

3.2 Electrical & Power Parameters

Parameter Category Technical Specifications
Power Supply Powered via DEIF PSM-1 module (backplane connection)
Input Voltage Range 100–600 V AC, 50/60 Hz (compatible with global grids)
I/O Interface Configurable: Digital I/O (DI/DO), Analog I/O (AI/AO)
Isolation Rating 2.5 kVrms (signal-to-ground)
Redundancy Dual redundant power inputs (switchover <5 ms)

3.3 Communication & Environmental Parameters

Parameter Category Technical Specifications
Communication Protocols Modbus RTU, CANopen
Communication Interfaces 2× RS-485, 1× CAN, 1× Ethernet
Display Compatibility Up to 3 DEIF display units (DU series)
Operating Temperature -25°C to +60°C (-13°F to 140°F)
Storage Temperature -40°C to +85°C (-40°F to 185°F)
Protection Rating IP65 (dust-tight, water jet-resistant)
Certifications CE, IECEx, DNV GL (marine & industrial standards)

4. Product Specifications

Specification Category Details
Physical Dimensions 30.5 mm (W) × 175 mm (H) × 120 mm (D) (6 TE width)
Weight ~0.47 kg (net); ~1.2 kg (shipping with packaging)
Mounting Type DIN rail or backplane mount (compatible with Delomatic-3 chassis)
Connectors – Communication: RS-485 (terminal block), CAN (M12), Ethernet (RJ45)

– Power: Backplane connector (PSM-1 compatible)

– I/O: Spring-clamp terminal blocks

User Interface Status LEDs (power, sync, fault); compatible with DEIF DU display units
Compatibility DEIF PSM-1 power modules, DU display units; 50/60 Hz generator sets
Configuration Software DEIF Power Studio (parameter tuning & monitoring)
Warranty 24-month manufacturer warranty (extendable to 3 years with service contract)

5. Typical Application Scenario

Cruise Ship Main Power SystemA cruise line deploys 4× DELOMATIC-3 DGU2 modules to control its 4× 1800 kW main generator sets:
  • Module Configuration: Each DGU2 connects to a generator, 2 DEIF DU display panels (engine room + bridge), and the ship’s navigation system via CANopen. Redundant power inputs (PSM-1 modules) and Ethernet links are enabled.
  • Synchronization & Load Management: When the ship departs, the DGU2s automatically start generators and synchronize them to the main bus in 30 seconds. During peak load (dinner service + cabin AC), the modules distribute 7200 kW evenly across all sets—maintaining 400 V/50 Hz with ±0.2 V deviation.
  • Fault Response: A generator experiences overcurrent due to a pump malfunction—the DGU2 triggers an alarm, isolates the faulty unit in 1.5 minutes, and redistributes load to the remaining three sets. No loss of power to cabins or navigation systems occurs.
  • Black Start Capability: During a shore power outage, the DGU2s initiate a black start—powering critical systems (navigation, lighting) within 2 minutes using one generator, then bringing others online sequentially.
The DELOMATIC-3 DGU2 is typically paired with DEIF PSM-1 power modules (for redundant 供电), DU display units (for local operation), and RS-485/CAN bus cables for system integration. If you need wiring diagrams for parallel generator synchronization, compatibility checks with specific generator brands (e.g., Caterpillar, Volvo Penta), or configuration guides for Modbus RTU communication, feel free to specify. Sharing your application (e.g., marine vs. backup power) will also help refine details like environmental sealing upgrades or custom protection logic!
Scroll to Top