Allen-Bradley 1746-OX8 Relay Output Module – 1250 VA Total Load Capacity Output Module

Allen-Bradley 1746-OX8 Relay Output Module – 1250 VA Total Load Capacity Output Module

The Allen-Bradley 1746-OX8 Relay Output Module​ is an 8-point relay output module for the Rockwell Automation SLC 500 family. It provides eight independently switched, galvanically isolated normally open relay contacts that the SLC 500 controller drives directly over the chassis backplane. Unlike transistor or triac output modules, which are tied to a specific voltage family and polarity, the Allen-Bradley 1746-OX8 Relay Output Module​ uses dry contacts: each output is a set of relay terminals that can switch an AC or DC load at the user’s chosen voltage, provided the load stays within the published ratings. This makes the module the universal-choice output for mixed-voltage panels and for loads where electrical isolation between the control system and the field device is a requirement rather than a preference.

Each of the eight relays in the Allen-Bradley 1746-OX8 Relay Output Module​ is rated at 2 A continuous per point, with a total module load capacity of 1250 VA. The contacts are specified for 250 V AC and 125 V DC operation, and are independently fused and individually replaceable. The nominal on-state delay is 16 ms and the off-state delay 16.5 ms, figures that reflect the mechanical nature of the relay and that must be accounted for in high-speed sequencing. The module is powered from the SLC 500 backplane—250 mA at 5 V DC—and requires no external supply for the outputs, which simplifies panel wiring and removes one potential point of failure. Two green status LEDs, two yellow fuse-status indicators and eight yellow point-status LEDs give immediate visibility into both the module state and the condition of each fuse.

Positioned within the SLC 500 digital output portfolio, the Allen-Bradley 1746-OX8 Relay Output Module​ occupies the slot between low-voltage transistor outputs and high-current AC modules. Its value lies in three properties that transistor outputs cannot match: true galvanic isolation, indifference to load polarity and voltage family, and the ability to carry a modest current through a mechanically clean contact. For asset owners maintaining long-lifecycle SLC 500 assets in water, food and beverage, metals, mining and discrete manufacturing, this makes the module one of the most useful spares to hold on site. A failed transistor output module is a single-voltage, single-polarity device; a failed Allen-Bradley 1746-OX8 Relay Output Module​ can affect solenoids, motor starter coils, indicator lamps, small contactors and alarm horns across an entire panel, which is precisely why a tested replacement must be available when the rack goes down.

Allen-Bradley 1746-OX8 Relay Output Module – 1250 VA Total Load Capacity Output Module

 

Technical Specifications

Parameter Name Parameter Value
Product Model Allen-Bradley 1746-OX8 Relay Output Module​
Manufacturer Rockwell Automation (Allen-Bradley)
Product Type Relay output module
Product Family SLC 500 (1746 series)
Number of Outputs 8, normally open (form A) contacts
Output Rating per Point 2 A at 250 V AC, 2 A at 125 V DC
Total Load Capacity 1250 VA
Maximum Switching Voltage 250 V AC, 125 V DC
Contact Type Dry, galvanically isolated relay contacts
On-State Delay 16 ms nominal
Off-State Delay 16.5 ms nominal
Contact Life 100,000 operations minimum at rated load
Fusing Individually fused per output, user-replaceable
Backplane Current Draw 250 mA at 5 V DC
Power Source SLC 500 chassis backplane (no external supply required)
Indicators 2 green status LEDs, 2 yellow fuse-status LEDs, 8 yellow point-status LEDs
Wiring Terminals Removable terminal block, 2 terminals per output
Mounting DIN rail mount / 1746 chassis slot
Dimensions (H × W × D) 118.5 × 34.6 × 87.9 mm (4.66 × 1.36 × 3.46 in)
Weight 0.17 kg (0.38 lb)
Operating Temperature 0 °C to +60 °C (32 °F to 140 °F)
Storage Temperature -40 °C to +85 °C (-40 °F to +185 °F)
Relative Humidity 5 % to 95 % non-condensing
Shock and Vibration 30 g operating shock; 2 g @ 10–500 Hz vibration
Certifications UL 508, CSA C22.2 No. 142, CE, C-Tick; CSA Class I Division 2 Groups A–D where marked

 

Main Features and Advantages

Universal load compatibility through dry contacts:​ The principal advantage of the Allen-Bradley 1746-OX8 Relay Output Module​ is that each output is a genuine relay contact rather than a semiconductor switch. The controller side is isolated from the load side, so a 120 V AC motor starter coil, a 24 V DC solenoid, a 48 V DC indicator and a 250 V AC alarm horn can all share the same module without regard to polarity or commoning. In a panel built over many years by different engineers, this universality prevents the costly and error-prone practice of keeping four different output module types in stock and hoping the right one is installed when a failure occurs.

Galvanic isolation and noise immunity:​ Because there is no direct electrical path between the backplane and the load terminals, the module contains transients, ground loops and common-mode voltage shifts that are endemic in panels with large motors and welding equipment. A contactor coil collapse or a VFD-induced transient on one output cannot propagate into the SLC 500 backplane. This is the reason relay outputs remain the preferred choice for interfacing electromechanical devices even where transistor outputs would offer faster switching: the electrical boundary is absolute, and it protects the controller rather than merely tolerating the disturbance.

Individually fused and independently visible outputs:​ Each of the eight outputs is fused separately, so a shorted solenoid or a miswired contactor coil takes out one point rather than the entire module. The two yellow fuse-status LEDs divide the module into fuse-monitoring groups, while the eight yellow point-status LEDs show the commanded state of every output. Together with the green status LEDs, this gives maintenance personnel a complete picture of module health without opening the panel door or connecting a programming device. In a darkened motor control centre, that visual information turns a twenty-minute fault search into a five-minute fuse replacement.

No external supply and simple wiring:​ The outputs are powered from the chassis backplane, so the module needs only the field load connections and the backplane seat. The removable terminal block allows pre-wiring on the bench and transfer to the replacement module in seconds, with no field conductor disturbed. For a panel that must be restored quickly, this is a decisive advantage over output modules that require a separately fused and distributed load supply.