Allen-Bradley 1734-IE2C POINT I/O 2-Channel Analog Current Input Module – Precision Signal Acquisition for Distributed Control Architectures

Allen-Bradley 1734-IE2C POINT I/O 2-Channel Analog Current Input Module – Precision Signal Acquisition for Distributed Control Architectures

The 1734-IE2C is a 2-channel analog current input module from Allen-Bradley‘s POINT I/O platform, a modular distributed I/O system designed for integration with ControlLogix, CompactLogix, and other Logix-based controllers via communication adapters such as 1734-AENTR EtherNet/IP . The 1734-IE2C accepts standard industrial current signals—4–20 mA and 0–20 mA—with 16-bit resolution, converting field transmitter data into digital values for use in process control, monitoring, and data acquisition applications .

Allen-Bradley 1734-IE2C POINT I/O 2-Channel Analog Current Input Module – Precision Signal Acquisition for Distributed Control Architectures

 

Application Scenarios

In a mid-sized chemical batch processing plant, a CompactLogix controller managed reactor temperature and pressure loops across three production bays. The existing analog input cards were centralized in a single control cabinet, requiring hundreds of meters of shielded twisted-pair cable to reach field transmitters scattered throughout the process area. Signal degradation and ground-loop noise caused occasional erratic readings that operators learned to ignore—a dangerous practice in a facility handling exothermic reactions. By deploying 1734-IE2C modules in local junction boxes near each reactor, engineers shortened analog cable runs to under 10 meters, eliminating the noise coupling that had plagued the centralized architecture. The 1734-IE2C modules communicated back to the controller through 1734-AENTR EtherNet/IP adapters, appearing as native I/O within the existing Logix project without gateway configuration. When a transmitter fault occurred on Reactor 2, the 1734-IE2C‘s built-in channel-level diagnostics flagged the underrange condition immediately, allowing operators to switch to manual control before the batch was compromised.

 

Parameter

Parameter Value/Description
Product Model 1734-IE2C
Manufacturer Allen-Bradley / Rockwell Automation
Product Category POINT I/O Analog Current Input Module
Input Channels 2 (single-ended, non-isolated)
Input Signal Range 4–20 mA (default), 0–20 mA (configurable per channel)
Resolution 16-bit, 0.32 µA/count (over 21 mA range)
Accuracy ±0.1% full scale at 25°C
Temperature Drift 30 ppm/°C
Data Format Signed integer, –32,768 to 32,767
Conversion Type Delta-sigma
Step Response 70 ms (60 Hz notch, default); 80 ms (50 Hz); 16 ms (250 Hz); 8 ms (500 Hz)
POINTBus Current 75 mA at 5V DC
Power Dissipation 0.6 W max at 28.8V DC
Terminal Base 1734-TB, 1734-TBS, 1734-TOP, 1734-TOPS
Mounting DIN rail (horizontal or vertical, no de-rating)
Operating Temperature –20°C to +55°C
Isolation No (channels not isolated from each other or system)