1732E-16CFGM12 AB
AB 1732E-16CFGM12 is a Compact I/O module with the following parameters:
-Number of input channels: 16, configurable as digital or analog inputs
-Number of output channels: None
-Input voltage range: selected based on the installed module, usually 24V DC
-Input type: can be configured as DC digital input or analog voltage or current input
-Input resolution: depends on the configured input type
-Integrated communication interface: EtherNet/IP
-Communication rate: 10/100 Mbps
-Power supply voltage: 24V DC
-Working temperature range: -20 ° C to+55 ° C
-External dimensions: Compact, approximately 35mm x 87mm x 130mm
-Weight: approximately 0.2kg

GE FANUC SERIES IC600BF923A IC600BF923 IC600YB923
GE FANUC IC600YB831A IC600YB831 IC600YB831K
NEW GE FANUC IC600YB843B ANALOG INPUT PLUG MODULE BOARD
GE FANUC IC600FP904 USPP IC600FP904
GE IC600LR605K
GE FANUC IC600MA500 NSPP IC600MA500
GE FANUC IC600FP800 USPP IC600FP800
GE FANUC IC600FP831 USPP IC600FP831

The power supply is used to convert AC power into DC power required within the PLC, and most PLCs use a switch type regulated power supply for power supply.
Central processing unit
The central processing unit (CPU) is the control center and core component of the PLC, and its performance determines the performance of the PLC.
The central processing unit (CPU) is composed of a controller, arithmetic unit, and register, all of which are concentrated on a single chip and connected to the input/output interface circuit of the memory through an address bus and control bus. The role of the central processing unit is to process and run user programs, perform logical and mathematical operations, and control the entire system to coordinate.
storage
Memory is a semiconductor circuit with memory function, which is used to store system programs, user programs, logical variables, and other information. The system program is a program that controls the PLC to achieve various functions, written by the PLC manufacturer and solidified into read-only memory (ROM), which cannot be accessed by users.
input unit
The input unit is the input interface between the PLC and the controlled equipment, serving as a bridge for signals to enter the PLC. Its function is to receive signals from the main command and detection components. The types of inputs include DC input, AC input, and AC/DC input.
output unit
The output unit is also a connecting component between the PLC and the controlled equipment. Its function is to transmit the output signal of the PLC to the controlled equipment, which converts the weak current signal sent by the central processing unit into a level signal and drives the execution components of the controlled equipment. The types of outputs include relay output, transistor output, and crystal gate output.
In addition to the above components, PLC also has various external devices according to different models, which are used to assist in programming, monitoring, and network communication. Commonly used external devices include programmers, printers, cassette tape recorders, computers, etc.