Woodward 5417-041 NetCon 12ft Discrete Cable – Woodward Dedicated Spare

Woodward 5417-041 NetCon 12ft Discrete Cable – Woodward Dedicated Spare

 

Application Scenarios

In a gas-compressor skid, the NetCon rack is located in the main enclosure, while the remote discrete panel—housing emergency-stop contacts, valve-limit verification, and skid-local alarms—is mounted 10 feet away on the frame www.changxincontrol.com. A technician used generic shielded pair cable and terminal blocks for the connection. Within three weeks, the DCS logged intermittent “discrete input flicker” whenever the VFD ramped. The root cause: a hand-made harness with incorrect pair twist, no strain relief, and shield grounded at both ends, creating a ground loop that injected VFD noise into the contact sense circuit www.changxincontrol.com. The solution was straightforward: replace the homemade cable with a Woodward 5417-041. The factory-terminated connector seated with correct polarity, shield bonded per Woodward convention, and the 12-ft reach landed cleanly in the remote panel. The flicker vanished after one start-up cycle—no card replacement, no software change, no “ghosts” www.changxincontrol.com.

 

Parameter Table

Parameter Value / Description
Product Model 5417-041
Manufacturer Woodward Inc., Fort Collins, Colorado, USA
Product Category NetCon low-density discrete signal cable / finished harness
Signal Class Discrete (contact, dry contact, on/off, permissive, trip/interlock)
Cable Length 12 ft (3.66 m)
Color / Jacket Gray PVC, industrial grade, UL VW-1 / IEC 60332-1 flame class
Connector A NetCon-compatible, metal shell, keyed, screw-locked (4-40 UNC)
Connector B NetCon-compatible mate or fanned discrete tails
Conductor Copper, tinned, 22–18 AWG (harness/revision-specific)
Shield Overall foil/braid shield with backshell bonding
Voltage Rating 600 V insulation rating (not signal rating)
Operating Temperature −40 °C to +85 °C
Storage Temperature −55 °C to +105 °C
EMC / Immunity IEC 61000-4-4 EFT, IEC 61000-4-5 surge envelopes
Minimum Bend Radius ≈ 8 × cable OD
Routing Distance ≥ 300 mm from VFD/power lines (parallel), 90° crossing
IP Rating IP20 (connector), none on cable body
Weight ≈ 0.6–2.0 kg (harness), ~3 kg with packaging www.cnplcdcs.com
Certifications CE / UL / RoHS on production builds
Lifecycle Active, low-volume custom-run part; lead time 4–8 weeks

 

Technical Principles and Innovative Values

  • Innovation Point 1: A harness, not a commodity cable – The 5417-041 is factory-pinned to NetCon convention, factory-terminated with bonded metal shells, and factory-tested for continuity and shorts. In a rack where one wrong discrete means an interlock is silently defeated, this is a safety feature, not just convenience www.changxincontrol.com.
  • Innovation Point 2: 12 ft is a system dimension – The 12-ft length matches the typical NetCon rack-to-remote-panel envelope. The 10-ft 5417-040 is too short for the next joint; longer runs leave excess coiled in trays, becoming EMI antennas. Good cable practice is built-in, not left to the installer www.changxincontrol.com.
  • Innovation Point 3: Discrete and analog are separate SKUs – Woodward sells 5417-040 for analog and 5417-041 for discrete. The pair count, shield topology, and pinout differ. This separation forces a two-second check that prevents “4–20 mA on a discrete harness” commissioning disasters www.changxincontrol.com.
  • Innovation Point 4: Metal shells and screw locks are anti-vibration features – NetCon cabinets live on skids, turbine decks, and compressor frames. Push-on connectors become intermittent within months. The 5417-041 uses keyed, jack-screw-locked mates that you feel seat and see torque applied www.changxincontrol.com.
  • Innovation Point 5: Makes the invisible layer testable – A suspected “I/O fault” becomes a five-minute loop: unplug the 5417-041 at the rack, ohm the pairs, check shield bond, swap the spare. It turns a ghost fault into a replaceable part—the definition of maintainable www.changxincontrol.com.
Scroll to Top