Technical Specifications
| Parameter Name | Parameter Value |
|---|---|
| Product Model | 750-P5-G5-D5-HI-A20-R-E-H |
| Manufacturer | GE Multilin (GE Vernova Grid Solutions) |
| Product Series | Multilin 750/760 Feeder Protection System / SR Family |
| Product Type | Digital Feeder Management Relay (Drawout) |
| Phase Current Inputs (P5) | 5 A secondary |
| Ground Current Inputs (G5) | 5 A secondary |
| Control Power (HI) | 88–300 VDC; 70–265 VAC @ 48–62 Hz |
| Analog Outputs (A20) | Eight (8) isolated 4–20 mA, programmable |
| Display (E) | Enhanced backlit LCD with improved keypad |
| Communication Protocols | Modbus RTU, DNP 3.0 Level 2 |
| Event Recording | 512 time-tagged events |
| Oscillography | Up to 32 power cycles (10 records) |
| Operating Temperature | –40°C to +60°C |
| Net Weight | Approximately 7.6 kg |
Main Features and Advantages
Comprehensive Protection Suite: The 750-P5-G5-D5-HI-A20-R-E-H integrates an extensive library of ANSI protection elements within a single hardware platform. Phase, neutral, and ground instantaneous and time-overcurrent elements form the foundation of the protection scheme, while the D5 advanced protection package adds voltage protection, frequency protection, synchrocheck, and arc flash detection capabilities . This consolidation means a single 750-P5-G5-D5-HI-A20-R-E-H can replace what previously required multiple discrete relays, reducing wiring complexity and panel space requirements.
Drawout Construction for Minimal Downtime: The 750-P5-G5-D5-HI-A20-R-E-H features a drawout case design that allows the relay chassis to be removed from its housing without disconnecting field wiring. This architecture is particularly valuable in critical distribution applications where protection must be restored rapidly following a device failure or firmware upgrade. Maintenance personnel can simply slide out the affected 750-P5-G5-D5-HI-A20-R-E-H and insert a replacement unit, with all current transformer, voltage transformer, control power, and communication connections remaining undisturbed .
Precision Built-in Metering: The 750-P5-G5-D5-HI-A20-R-E-H provides high-accuracy metering of voltage, current, power, power factor, and harmonics, eliminating the need for separate panel meters or transducer installations. Eight programmable 4-20 mA analog outputs allow critical measured parameters to be transmitted directly to SCADA systems, PLCs, or distributed control systems without additional signal conditioning equipment. This metering capability also supports power quality analysis, enabling operators to identify harmonic distortion, voltage unbalance, or load imbalance issues before they cause equipment damage .
Harsh Environment Protection: The H suffix indicates that the has received conformal coating on its circuit boards, protecting sensitive electronics from humidity, chemical vapors, and conductive dust. This protection is particularly important in industrial environments such as chemical plants, wastewater treatment facilities, and coastal installations where atmospheric contamination can rapidly degrade unprotected circuit assemblies .
Wide-Range Control Power: The HI control power option accepts 88-300 VDC or 70-265 VAC at 48-62 Hz, enabling the to operate directly from common station battery voltages including 110 VDC, 220 VDC, and 250 VDC without requiring external power supplies or voltage converters. This flexibility simplifies installation and reduces the number of spare components required in inventory .