ABB 3BHE012276R0101 UAD143A101 PCB Board – Internal Circuit Board for S800 I/O AI843 16-Channel Analog Input Module

ABB 3BHE012276R0101 UAD143A101 PCB Board – Internal Circuit Board for S800 I/O AI843 16-Channel Analog Input Module

Product Overview

The ABB 3BHE012276R0101 (UAD143A101)​ is the internal printed circuit board assembly of the ABB AI843 analog input module, belonging to ABB’s S800 I/O distributed I/O platform and widely deployed within ABB Symphony Plus DCS and System 800xA architectures. While the AI843 module is the field-facing unit that mounts on an S800 I800 rack / SDCS-PIN-48 series base (e.g. 3BSE004939R1012), the ABB UAD143A101​ PCB is the core signal-conditioning and conversion engine inside that module — and is separately stocked as a spare / service-replacement board for maintenance teams who repair AI843 units rather than replacing the whole module.

Functionally, the ABB 3BHE012276R0101​ PCB carries 16 independently isolated analog input channels, each with its own 16-bit ADC, supporting software-configurable signal types on a per-channel basis: 4–20 mA, 0–10 V, RTD (Pt100/Pt1000/Cu10 etc.) and thermocouple (TC, Types J/K/T/E/S/B/R/N). This eliminates the traditional need for separate AI, RTD and TC card types — a single ABB UAD143A101​ PCB-equipped AI843 can mix pressure transmitters on the first eight channels and temperature probes on the last eight, all within one 16-channel envelope. Channel-to-channel and channel-to-bus isolation exceed 2.5 kV RMS, suppressing ground loops and common-mode noise in multi-earthed plant layouts.

The ABB 3BHE012276R0101​ operates from the S800 I/O backplane 24 V DC supply, draws ≤15 W, and supports HART transparent pass-through on each channel so that HART-enabled field instruments can be polled from the control system or handheld communicator without extra wiring. Integration with ABB Control Builder Plus auto-detects the module, exposing channel-level forcing, scaling, open-sensor detection and diagnostic states. For asset managers, stocking the ABB UAD143A101​ PCB as a line-spares item extends AI843 service life at roughly one-third the cost o

ABB 3BHE012276R0101 UAD143A101 PCB Board – Internal Circuit Board for S800 I/O AI843 16-Channel Analog Input Module

 

Technical Specifications

Parameter Value
Product Model ABB 3BHE012276R0101​ (PCB ID: UAD143A101)
Manufacturer ABB
Product Type PCB Circuit Board Assembly (for S800 I/O AI843 Analog Input Module)
Parent Module ABB AI843 (16-channel Analog Input, S800 I/O)
Signal Types (per channel, SW-configurable) 4–20 mA, 0–10 V, RTD (Pt100/Pt1000/Cu10/Cu100/Ni100), TC (J/K/T/E/S/B/R/N)
Number of Channels 16 analog input channels
ADC Resolution 16 bit
Conversion Accuracy ≤ ±0.1% of span
Channel Isolation > 2.5 kV RMS (channel-to-bus, channel groups)
HART Support HART 5/6/7 transparent pass-through (all channels)
Operating Voltage 24 V DC (backplane, via S800 base)
Power Consumption ≤ 15 W (typical, full 16-ch load)
Communication (to controller) S800 I/O internal bus (via SDCS-PIN-48 base)
Operating Temperature –5 °C to +60 °C (module level); PCB storage –40 °C to +85 °C
Enclosure / Mounting Plugs into AI843 housing; AI843 mounts on S800 rack / DIN rail via base
Standards CE, UL, RoHS, IEC 61131-2, ABB S800 I/O mechanical/electrical spec
Compatible Base SDCS-PIN-48-S/D series (e.g. 3BSE004939R1012)

 

Main Features and Advantages

Software-configurable universal analog inputs:

The ABB 3BHE012276R0101 (UAD143A101)​ PCB gives each of its 16 channels an independent 16-bit ADC and its own signal-conditioning front end, so the AI843 can be software-tasked at the channel level — e.g. Ch1–Ch8 as 4–20 mA pressure transmitters, Ch9–Ch12 as Pt100 RTDs, Ch13–Ch16 as K-type TCs — without jumper changes or hardware variants. For spare planners this collapses three card types (AI, RTD, TC) into one stock-keeping unit, reducing obsolescence and shelf diversity.

Channel-grade electrical isolation:

Each channel group on the ABB UAD143A101​ PCB is galvanically isolated from the backplane and from neighbouring groups at >2.5 kV RMS. In plants where field sensors land on different earth grids (turbine island vs. boiler island, or skid-mounted packages tied to local ground rods), this isolation stops ground-loop currents and prevents a fault on one channel from propagating to others — a frequent pain point with non-isolated or group-isolated-only designs.

HART transparent pass-through:

All 16 channels on the ABB 3BHE012276R0101​ PCB carry HART superimposed on the 4–20 mA loop, passed transparently to the controller and to HART multiplexer / handheld tools. This enables wired HART device diagnostics, valve positioner parameterisation and calibration checks without breaking into the loop or adding HART modems at the rack — a strong advantage in FDA/GMP-regulated pharma or in remote oil & gas wellpad I/O where truck rolls are expensive.

Deep 800xA / Symphony Plus integration:

When the ABB UAD143A101​ PCB is seated inside its AI843 housing on an base, Control Builder Plus auto-enumerates the module, exposes channel-level forced-value, scaling, open-sensor detection, wire-break alarms and ADC self-test results in the standard diagnostic tree. No GSD/editing, no third-party mapping layers — it’s native. For legacy Symphony Plus retrofits migrating toward 800xA, the ABB 3BHE012276R0101​ PCB gives a drop-in signal path that doesn’t force rewiring the field side.

Service-friendly spare form factor:

Because the ABB 3BHE012276R0101​ is sold as the bare PCB assembly (rather than a cased module), maintenance shops with component-level repair capability can swap a damaged UAD143A101 into a harvested shell, re-calibrate and return the module to stock — cutting lead-time versus ordering a fresh from ABB and avoiding the waste of scrapping an otherwise-good housing, connector and labelling. For plants under cost-pressure, this is the pragmatic mid-life strategy.

ABB 3BHE012276R0101 UAD143A101 PCB Board – Internal Circuit Board for S800 I/O AI843 16-Channel Analog Input Module1

Scroll to Top