TRICONEX 3721

TRICONEX 3721

Product Name

TRICONEX 3721 32-Channel Differential Analog Input Module; TMR Safety AI Card for 0–5 VDC/–5 to +5 VDC (TRICONEX by Schneider Electric Process Safety).

Product Description

The TRICONEX 3721 is a high-reliability, 32-channel differential analog input module engineered for TRICONEX TMR safety controllers. It is purpose-built to acquire DC-coupled voltage signals (0–5 VDC or –5 to +5 VDC) from field transmitters, sensors, and transducers in safety-critical applications, enabling precise monitoring and closed-loop safety interlocks/shutdowns.
Key features include programmable 12-bit/14-bit resolution for balancing precision vs. update speed, 10 ms full-channel update rate for deterministic signal capture, and continuous overvoltage protection (150 VDC/115 VAC) to safeguard against field-side transients. It leverages TMR backplane synchronization and majority voting to eliminate single points of failure, supports hot-swappable installation for online maintenance without SIS downtime, and provides built-in diagnostics for channel health and communication status.
Compliant with IEC 61508 SIL 3 and designed for TRICONEX TMR chassis integration, the 3721 ensures data integrity and fault tolerance in harsh industrial environments, making it ideal for retrofits or expansions of existing SIS where high-channel-density analog input and safety certification are mandatory.

Key Parameters & Specifications (Consolidated Table)

Category Specification Notes
Manufacturer TRICONEX (Schneider Electric Process Safety) Safety-focused TMR SIS specialist
Product Type 32-channel differential analog input module (AI) TMR-compatible; DC-coupled
Primary Function Voltage signal acquisition; TMR voting; diagnostics; overvoltage protection For safety-critical SIS monitoring
Input Channels 32 differential, DC-coupled Isolated to prevent cross-channel interference
Input Voltage Ranges 0–5 VDC or –5 to +5 VDC (programmable via TriStation) Over-range measurement ±6% typical
Resolution 12-bit or 14-bit (programmable) Selectable via configuration software
Accuracy < 0.15% of FSR (0 °C to 60 °C) Temperature-compensated for stable performance
Update Rate 10 ms (all channels) Deterministic sampling for SIS timing
Common Mode Rejection (CMR) ≥ 85 dB (DC to 100 Hz) Minimizes noise from ground loops and EMI
Input Impedance ≥ 10 MΩ (DC, powered); ~140 kΩ (power-off, typical) Compatible with most industrial sensors/transmitters
Overvoltage Protection 150 VDC/115 VAC continuous Protects module from field-side transients
Power Supply Backplane-powered by TRICONEX TMR chassis No external power required; ~15 W max (logic power)
Compatibility TRICONEX TMR safety controller chassis Verify firmware version for full integration
Environmental Ratings Operating Temp: 0 °C to 60 °C (rated); Storage Temp: –40 °C to +85 °C; Humidity: 5–95% RH (non-condensing); Vibration: Per IEC 60068-2-6 (5 g RMS, 5–500 Hz) Install in climate-controlled cabinet (IP20)
Mechanical Specifications Form Factor: TRICONEX standard chassis module; Mounting: TRICONEX TMR chassis slot; Protection Rating: IP20 (cabinet-mounted only); Hot-swappable: Yes Supports online maintenance without SIS shutdown
Safety Certifications IEC 61508 SIL 3; TÜV Rheinland certified; FM Approved; CSA Certified Compliant with global SIS safety standards
Diagnostic Features Channel open/short detection; overvoltage alerts; self-diagnostics; TMR voting status Enables rapid fault troubleshooting and predictive maintenance

Critical Installation & Operation Notes

TRICONEX 3721

  1. Channel Configuration: Use TriStation software to set input range (0–5 VDC/–5 to +5 VDC) and resolution (12-bit/14-bit) per channel group; mismatched ranges may cause signal clipping or measurement errors.
  2. Overvoltage Limits: Do not exceed 150 VDC/115 VAC continuous on inputs; transient suppressors may be required for high-voltage surge-prone environments.
  3. Wiring Best Practices: Use shielded twisted-pair cables for differential inputs; ground shields at the sensor/transmitter end to minimize EMI. Keep analog and power cables separated to avoid cross-talk.
  4. Hot-Swap Procedure: Follow TRICONEX safety guidelines for hot-swapping—ensure the module is properly aligned with the chassis slot to prevent backplane pin damage or SIS disruption.
  5. Firmware Compatibility: Match module firmware with TMR controller firmware to ensure reliable communication and correct diagnostic reporting.

Recommendations

  • Installation: Insert the module into a designated analog input slot in the TRICONEX TMR chassis; wire differential inputs with shielded twisted-pair cables; verify isolation and ground connections before powering on.
  • Commissioning: Use TriStation to configure ranges, resolution, and alarm limits; calibrate each channel with a precision vo