Key Parameters & Specifications (Consolidated)

Category Specification Notes (Critical Distinctions)
Manufacturer ABB Process Automation Pressductor® tension measurement lineage; PFTL 101B 2.0kN=base model+rated capacity
Product Type Shear beam load cell (web tension sensor) Pressductor® technology; not a controller or I/O module
Rated Capacity (Nominal Load) 2.0 kN (≈450 lbf) Full-scale measurement range; do not exceed rated overload limits
Accuracy & Linearity ±0.25% FSO (typical); linearity ≤0.1% FSO Precision class for closed-loop tension control
Output Signal Standard: mV/V (strain gauge bridge); optional 4–20 mA (with signal conditioner) mV/V requires external excitation & conditioning; 4–20 mA is a system-level option
Excitation Voltage 10–15 V DC/AC (typical); consult datasheet for exact range Stable excitation ensures accuracy; use regulated supply
Construction & Material Stainless steel (316L typical); laser-welded hermetic seal Corrosion-resistant for wet/chemical environments
Protection Rating IP67 (dust-tight, protected against temporary immersion) Suitable for washdown and harsh industrial zones
Operating Temperature -20 °C to +70 °C (standard); -40 °C to +80 °C (extended range variants) Confirm with unit label for your specific unit
Mounting Shear beam bolted mounting (flange/foot mount per ABB drawings) Use torque values per ABB guidelines to avoid preload errors
Overload Capacity Typically 150% of rated capacity (measurement direction); transverse overload rated per ABB specs Prevents damage from process spikes; use mechanical stops for extreme transients
Weight ~0.4–0.5 kg (typical; per unit label) Net weight of the load cell; mounting hardware not included
Compliance & Certifications ABB Pressductor safety & EMC standards; RoHS, CE (region-dependent) Verify local certifications for regional deployment

Critical Notes (Avoid Common Mistakes)

TRICONEX  3720

  1. Output Type: Standard is mV/V (strain gauge bridge); 4–20 mA requires an external signal conditioner or a pre-configured variant. Do not mix signal types without proper conditioning.
  2. Excitation: Use a regulated 10–15 V DC/AC supply; voltage drift degrades accuracy. Install surge protection and filtering in high-EMI environments.
  3. Mounting Preload: Avoid excessive preload during installation; follow ABB’s torque and alignment guidelines to ensure shear force is applied along the sensing axis.
  4. Overload Protection: Operate within rated capacity and overload limits; add mechanical stops for shock loads to prevent permanent damage.

Recommendations

  • Installation: Mount on a rigid base with proper alignment to the web path; ensure shear force is applied axially. Use shielded cables for mV/V signals and ground per ABB’s wiring diagrams.
  • Commissioning: Verify excitation voltage, zero balance, and linearity across the operating range; calibrate with known weights or tension references before putting into service.
  • Maintenance: Perform quarterly checks on signal stability, zero drift, and cable integrity; clean regularly in dusty/washdown environments; replace with ABB-approved spares (same model/capacity) if drift or damage occurs.